2i, 2i-N Aerosol Photometer
- Product Overview
- Scanning Probes: iProbe or iProbe Plus
- Enhanced Calibration and Performance Verification
- Product Specifications
- Part Numbers / Accessories
Applications
- Pharmaceutical manufacturing
- Medical facilities and cleanrooms
- Biosafety cabinets and fume hoods
- Nuclear facilities
Options
- iProbe or iProbe Plus with 12-ft cable
- The 2i-N model, with sealed sample train, is compatible with ASME N511, ASME 510, ASME 509, and ASME AG-1
Key Features & Benefits
- Supports 21 CFR Part 11 requirements (iProbe Plus)
- Enhances data integrity, quality control, and security
(iProbe Plus) - Large, 4.3-inch color touchscreen (iProbe Plus)
- Better accuracy, precision, and quality control with enhanced calibration and verification
- Lightweight, portable, and rugged aerosol photometer
- Improves efficiency and safety with upstream/downstream/clear valve controls from the probe (patented)
Click the video to learn more.
The iProbe or iProbe Plus allows the user to control the 2i from the scanning probe.
Quality Control, Traceability, and Security
The iProbe Plus creates a unique record of each filter scanned. Each record includes key identifiers (IDs) and important scan data for quality control and traceability.
Scan Traceability IDs
|
Additional Data for Each Scan
|
- Supports 21 CFR Part 11 compliance through encryption, password protection, and data protection.
- Offers optional password protection and encryption of the test data.
- Reporting: Can save approx. 150,000 scans. Each saved leak scan is in a .CSV and .PDF file format for easy analysis.
Efficiencies, Ease of Use, and Safety
Upstream/Downstream/Clear Controls:
The iProbe Plus allows the user to actuate the upstream/ downstream/clear valves through the touchscreen (patented feature). This improves efficiency and safety by eliminating the need to actuate the valves through the 2i base unit.
Additional User Conveniences:
- All firmware updates are installed via USB-A memory stick
- Unique 10-second “rewind” button prevents the saving of accidental alarm events (patent pending)
- Ergonomic handle with finger grooves and thumb rest
- Important information displayed on screen, such as Max % Leakage; Filter ID; Elapsed Scan Time
Photometers help protect human health. How you calibrate them matters. ATI’s new CALIBRA™ system provides significant advances in 2i calibration, and a new multi-point aerosol linearity verification testing capability (patent pending).
Better Performance and Consistency
Precision = More Consistent Measurement Photometers are calibrated with an aerosol source. ATI’s new CALIBRA™ 800 Precision Aerosol Source achieves a more stable aerosol concentration and particle size distribution over time, resulting in improved photometer consistency. Accuracy = the Right Measurement Photometers are calibrated against a gravimetric reference standard. The new ATI CALIBRA™ System enables a more accurate gravimetric measurement through automated control of the process and stringent methodology. |
Better Quality Control and Reduced Risk
ATI’s Linearity Verification Testing (LVT) service measures the instrument’s photometric and electronic response throughout its operating range. Together these tests provide a complete linearity verification that reduces quality risks, with documentation that strengthens your Quality Assurance program.
Trust in ATI
ATI is the world’s leading photometer manufacturer, with ISO 9001 certification and ISO 17025 accreditation (coming soon in 2024!). ATI’s high-quality calibrations and multi-point verification tests provide a clear and comprehensive record of photometer performance. |
|
ATI’s CALIBRA™ system for photometer calibration |
Product Specifications | |
---|---|
Dimensions (L x W x H) | 25.7 cm x 33 cm x 15.2 cm (13 in. x 10.1 in. x 6 in.) |
Weight | 8.6 kg (19 lbs) |
Power | 100 to 250 Volts AC, 50/60 Hz automatic adjustment 0.5 amps @ 120V, 0.25 amps @ 240V |
Auto Zero | Automatically establishes zero reading at startup |
Alarm | User selectable audible, visual, and vibratory |
Flow Control | 1 cfm (28.3 lpm) +/- 10% |
Reagent Settings | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin |
Dynamic Range | 0.0001 mg/m3 (µg/l) to 120 mg/m3 (µg/l) |
Accuracy | 1% of readings (0.01% to 100%) |
Repeatability | 0.5% of readings > 0.01% to 100% |
Light Source | Solid state, rated for life of instrument |
Data Output | Thermal printer, USB (2i base unit) |
Data Storage & Retrieval | iProbe Plus |
Standards Compliance | |
Industry | ISO 14644-3, NSF-49, IEST-RP-CC034, EN 12469 |
Electrical & Safety | CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED Canada ICES-003 Issue 7 |
Part Numbers & Ordering Information | ||
---|---|---|
2i, 2i-N Photometer & Ensembles | Description | Part Number |
2i (120v) | Digital Photometer (120v) | 9300241 |
2i (220v) | Digital Photometer (220v) | 9300242 |
2i-N (120v) | Digital Hazardous Environment Photometer (120v) | 9300246 |
2i-N (220v) | Digital Hazardous Environment Photometer (220v) | 9300247 |
iProbe Plus (only) | iProbe Plus (only) | 9300538 |
iProbe (only) | iProbe (only) | 9300248 |
2i Ensemble with iProbe Plus (120v) | 2i Photometer (120v), iProbe Plus, Heavy Duty Transport Case (Small, no wheels) | 9300529 |
2i Ensemble with iProbe Plus (220v) | 2i Photometer (220v), iProbe Plus, Heavy Duty Transport Case (Small, no wheels) | 9300530 |
2i Ensemble with iProbe (120v) | 2i Photometer (120v), iProbe, Heavy Duty Transport Case (Small, no wheels) | 9300235 |
2i Ensemble with iProbe (220v) | 2i Photometer (220v), iProbe, Heavy Duty Transport Case (Small, no wheels) | 9300240 |
2i-N Ensemble with iProbe Plus (120v) | Digital Hazardous Environment Photometer (120v), iProbe Plus, Heavy Duty Case (Small, no wheels) | 9300533 |
2i-N Ensemble with iProbe Plus (220v) | Digital Hazardous Environment Photometer (120v), iProbe Plus, Heavy Duty Case (Small, no wheels) | 9300534 |
2i-N Ensemble with iProbe (120v) | Digital Hazardous Environment Photometer (120v), iProbe, Heavy Duty Case (Small, no wheels) | 9300244 |
2i-N Ensemble with iProbe (220v) | Digital Hazardous Environment Photometer (220v), iProbe, Heavy Duty Case (Small, no wheels) | 9300245 |
2i Aerosol Photometer Accessories | ||
---|---|---|
# | Description | Part Number |
1 | Small Case, holds a 2i Photometer and iProbe or iProbe Plus |
9300258 |
2 | Combo Case, holds a 2i Photometer, iProbe or iProbe Plus, thermal printer, 5D (p/n 9300474) or 4B (p/n 4300475) generator, regulator, hose adapter |
9300474 or 9300475 |
3 | Large Case, holds a 2i Photometer, iProbe or iProbe Plus, and thermal printer |
9300243 |
4 | Thermal printer | 9300249 |